Related Products
Product Name:Spectrum analysis apparatus
Product Type:Optical Analysis Kit
Product Model:BIX-8802
Brands:Brolight
Applications:Ultrafast Laser/High-speed Research/Spectroscopy
Introduction
BIX-8802 is a spectrum analysis apparatus designed for physics, chemistry, biology, environment labs and scientific research in university and college. It also can be used for industrial spectrum testing. This apparatus can analyze emitting spectrum, transmission spectrum and reflection spectrum. It’s modular designed with simple structure and flexible configuration.

Feature
● Modular designed with flexible configuration
● Can be used to measure spectrum of light source, solid or liquid material’s transmission spectrum and reflection spectrum
● Wavelength can be chosen from 200nm to 1100nm
● Customized products is available

Emitting Spectrum

The light couples into the spectrometer through the optical fiber directly so that the spectral data of the light source can be obtained.

Applications:
● Spectrum of laser
● Spectrum of LED
● Spectrum of sunlight
● Spectrum of other light source

                                   Standard Hg lamp

Order Information
No Description Model# Qty. Notes
1 FiberSpectrometerWavelength 200nm-1100nmOptical resolution 0.1nm-1nm BIM-60/BIM-66 series 1 Determined by the wavelength and resolution
2 Quartz Optical, L1.5m, Φ600μm BIM-6102 2 -

Liquid samples transmissuon spectrum

Using the spectrometer to measure the tungsten as reference spectrum, it can measure the sample’s transmission spectrum. Then you can get the transmissivity curve and absorptivity curve by the software.
Applications
The component analysis and concentration measurement of chemicals, food or water.

 
                       Reference spectrum                                         Transmission spectrum of CuSO4 solution
Order Information
No Description Model# Qty. Notes
1 Fiber Spectrometer, Wavelength 200nm-1100nm, Optical resolution 0.1nm-1nm BIM-60/BIM-66 series 1 Determined by the wavelength and resolution
2 Quartz Optical, L1.5m, Φ600μm BIM-6102 2 -
3 Tungsten Light SourceⅡ, with the focusing lens, 400nm-2000nm, 10W BIM-6202 1 -
4 10dB Attenuator BIM-7921 1 -
5 Cuvette mount BIM-6305 1 -
6 Plastic Cuvette, 12.5 mm×12.5 mm×45 mm, (6EA) BIM-6301 1 -
7 Samples - - User-supplied

Solid samples transmission analysis

Using the spectrometer to measure the tungsten as reference spectrum, it can measure the sample’s transmission spectrum. Then you can get the transmissivity curve by the software.

 
                        Reference spectrum                                                 Transmission spectrum of filter

Applications
● The transmissivity, central wavelength and bandwidth of optical filter, sunglasses or car window films
● Component analysis of solid samples
Order Information

No Description Model# Qty. Notes
1 Fiber Spectrometer, Wavelength 200nm-1100nm, Optical resolution 0.1nm-1nm BIM-60/BIM-66 series 1 Determined by the wavelength and resolution
2 Quartz Optical, L1.5m, Φ600μm BIM-6102 2 -
3 Tungsten Light SourceⅡ, with the focusing lens, 400nm-2000nm, 10W BIM-6202 1 -
4 10dB Attenuator BIM-7921 1 -
5 Cuvette mount BIM-6305 1 -
6 Samples - - User-supplied

Solid samples reflection analysis

Using the spectrometer to measure the tungsten as reference spectrum, and then measure the sample’s reflection spectrum. The reflectance curve will be got by software.

                           Reference spectrum                                                Reflection spectrum of red paper

Applications
● Component analysis of solid samples
● Color measurement of paper, textile or oil paint (Developing)
Order Information

No Description Model# Qty. Notes
1 Fiber Spectrometer, Wavelength 200nm-1100nm, Optical resolution 0.1nm-1nm BIM-60/BIM-66 series 1 Determined by the wavelength and resolution
2 Reflection Quartz Fiber (Single Core), L 1.5m, Φ600μm BIM-6103 2 -
3 Tungsten Light SourceⅡ, with the focusing lens, 400nm-2000nm, 10W BIM-6202 1 -
4 Double Channels Reflection Mount Φ150mm×13mm BIM-6303 1 -
5 Diffuse Reflectance Standard,Φ40mm, R97% (350nm-2000nm) BIM-6304 1 -
6 Samples - - User-supplied
Specification
Description Model# Parameters
Fiber Spectrometer BIM-60/BIM-66 series Please see Fiber Spectrometer's introduce
Quartz Optical BIM-6102 L1.5m, Φ600μm
Tungsten Light Source BIM-6202 With the focusing lens, 400nm-2000nm, 10W; Maximum voltage: 12V DC; 2000 hours; SMA905 connector; Dimension: 100mm × 60mm × 34.5mm; 0.2Kg
Cuvette mount BIM-6305 140mm*140mm*40mm
Plastic Cuvette BIM-6301 6EA, 12.5 mm×12.5 mm×45 mm
SolidSample Transmission Mount BIM-6302 200mm*78mm
Double Channels Reflection Mount BIM-6303 Φ150mm×13mm
Diffuse Reflectance Standard BIM-6304 Φ40mm, R97% (350nm-2000nm)
Reflection Quartz Fiber BIM-6103 Single Core, L 1.5m, Φ600μm
Parts List
No . Description Moel# Qty .
1 Fiber Spectrometer,Wavelength 200nm-1100nm,Optical resolution 0.1nm-1nm BIM-60/BIM-66 series 1
2 Quartz Optical, L1.5m, Φ600μm BIM-6102 1
3 Reflection Quartz Fiber (Single Core), L 1.5m, Φ600μm BIM-6103 2
4 Tungsten Light SourceⅡ, with the focusing lens,400nm-2000nm, 10W BIM-6202 1
5 10dB Attenuator BIM-7921 1
6 Plastic Cuvette, 12.5 mm×12.5 mm×45 mm,(6EA) BIM-6301 1
7 Solid Sample Transmission Mount, L300mm BIM-6302 1
8 Double Channels Reflection Mount Φ150mm×13mm BIM-6303 1
9 Diffuse Reflectance Standard,Φ40mm, R97% (350nm-2000nm) BIM-6304 1
10 Cuvette mount BIM-6305 1